Those listed below are our PROUD SatelliteGuys GOLD Sponsors!
Applied Instruments DishStore.NET glorystar.tv satelliteavgs tele-satellite.com
Have a News Scoop For Us? >>> CONTACT US! <<<

Welcome HOME to SatelliteGuys.US!


  •  » Looking for help picking a satellite company?
  •  » Need Help with your Satellite System?
  •  » Need Advice on your Home Theater Setup?
  •  » Looking for the latest industry news and rumors?

...then you have come to the right place!
DIRECTV, DISH Network, FTA Satellite, Cable TV, HDTV even 3DTV...
We Can Help! We are known as America's Satellite Information Source!
YES! I want to register an account for free right now!
p.s.: Registered members see a lot less ads! REGISTER TODAY!

Results 1 to 3 of 3
  1. #1
    boomer_106's Avatar
    boomer_106 is offline SatelliteGuys Senior
    Join Date
    Mar 17th, 2005
    Posts
    856

    Help troubleshooting actuator

    ADVERTS
    First let me explain the problem the best I can. A couple of days before Christmas we were due to have some freezing rain. I wanted my dish on Galaxy 19 for the weekend so I thought to myself, I better move this over there now in case the actuator gets froze up from the rain. The ice didn't turn out to be that serious but, low and behold when I went to move the dish, I got an actuator error. I went out and figured I'll just break whatever ice is there loose and be back in business. There wasn't any ice there.



    The receiver is the Uniden Supra. The acutator is a Superjack QARL 3024+. I tried to move the dish while standing out there and the motor made no noise at all. I could however hear the servo moving. I tried disconnecting the big red and white wires at the actuator and using a battery charger to move the dish and it wouldn't move. I tried using my multimeter at the back of the receiver and measuring for DC voltage where the motor wires are and, there is nothing. I don't see any circuit breaker or anything. I took the red and white motor wires off the Supra and measured the terminals themselves and there is nothing.

    Is this the proper way to test? Do I have to mess with any of the small wires while performing this test? At this point I'm scratching my head because the actuator doesn't move with a battery charger yet it also seems like the Receiver isn't outputting voltage. They can't both have gone bad at the same time.

    If you can help me get troubleshooting this correctly where I can eliminate one part as the cause or not, it would help alot. I don't want to just order an actuator and find out the receiver isn't outputting. Perhaps the Supra needs to be reset or something because it encountered a bound up actuator?
    10 ft BUD. Uniden Supra analog c/ku, Pansat 9200 HD, Azbox Elite, chaparral co-rotor 2, Astrotel Precision Model PMJ-LNB (C) 15 K noise. Eagle Aspen 770 KU O.6 DB LNB

  2. # ADS
    Paying The Bills With Google Adsense Circuit advertisement
    Join Date
    Always
    Posts
    Many
     
  3. #2
    tvropro is offline SatelliteGuys Guru
    Join Date
    Mar 9th, 2007
    Posts
    6,871
    Here is a file I have that I got off the net some time ago this should help.

    *************************
    MOTOR VOLTAGE
    (1) Unplug your IRD/Receiver/Actuator Control from the electrical
    outlet and remove all cabling. Place the unit where it can easily
    be worked on and connect the video out to a monitor, if the unit
    has on-screen graphics.
    (2) Plug the unit back into the AC
    (3) Take your volt meter and set it at the 100 Volts DC.
    (4) Place your meter probes on the screws or in the spring loaded
    terminals of the Motor Control. It could be labeled: Motor; MTR;
    M1 & M2, etc.
    (5) Initiate your dish to move...you should hear the relay within the unit
    make a "click" noise. Likely you will hear two clicks, the first would
    be the relay, and the 2nd would be the unit shutting down to deliver an
    "actuator error" reading.
    (6) At the first "click", your meter should read +36 VDC. Your meter
    should drop to 0 at the second "click".
    (7) If you heard the "Clicks" but there was no voltage displayed on your
    meter, check the fuse or the circuit breaker & retest.
    (8) If when the test is performed again, you still have no voltage, you
    have a problem within your unit.

    TESTING ACTUATOR SYSTEMS

    SENSOR VOLTAGE
    (1) Follow the first two steps outlined in the MOTOR VOLTAGE testing.
    (2) Take your volt meter and set it at the 10 Volts DC.
    (3) Place your meter probes on the screws or in the spring loaded
    terminals of the Actuator sensor & ground. It could be labeled:
    Pulse & GND, Sensor & Gnd, ETC.
    (4) The meter should read between 6 & 8 VDC, typically. Your receiver,
    IRD, actuator control is not functioning properly if your readings are
    not in this range.

    COUNTING CIRCUIT
    PROCEDURE A
    (1) Follow the first two steps outlined in the MOTOR VOLTAGE testing.
    (2) Insert or connect wire at the sensor terminal
    (3) Tap the wire you just connected at approximately two taps per second
    against a metal surface on the unit
    (4) While tapping the wire, command the unit to move the dish
    (Make sure you are tapping the wire PRIOR to commanding the unit to
    move.)
    (5) Your counting signifier should change on the panel of the unit or
    on the monitor screen as you are simulating a working sensor.
    (6) If your counting signifier does not change, try Procedure B before
    shipping the unit in for repair.

    PROCEDURE B
    (1) Follow the first two steps outlined in the MOTOR VOLTAGE.
    (2) Insert a working sensor from a tested actuator motor. Place one
    lead on the sensor or pulse terminal. Place the other lead on the
    GND terminal.
    (3) With the sensor connected, command the unit to move the dish
    (4) Your counting signifier should change on the panel of the unit or
    on the monitor screen as you are using a working sensor.
    (5) If your counting signifier does not change, try Procedure C before
    shipping the unit in for repair.

    PROCEDURE C
    (1) Follow the first two steps outlined in the MOTOR VOLTAGE.
    (2) Take a working actuator arm or a working actuator motor and by using
    jumper wires, connect it directly to your receiver/IRD/actuator.
    (3) Connect both motor wires (typically larger gauge than sensor wires)
    & connect the sensor wires to pulse or sensor and ground.
    (4) Command the unit to move the dish
    (5) Your counting signifier should change on the panel of the unit or
    on the actuator monitor screen and the motor should be running.
    If your actuator motor is still attached to the telescoping shaft,
    it should be moving. Try both East and West movement commands.
    (6) If your counting signifier does not change, and the motor does not run,
    you will need to likely send the unit in for repair.
    (7) If the motor runs but the shaft (if connected to motor) does not move,
    you have a problem with your actuator arm and probably not the unit
    itself.

    *********************

    One last thing Im adding if the battery charger don't move the dish at the dish, either the motor is froze or brushes are shot.

  4. #3
    boomer_106's Avatar
    boomer_106 is offline SatelliteGuys Senior
    Join Date
    Mar 17th, 2005
    Posts
    856
    Thread Starter
    Thanks alot TVRO. That should help alot. That's an excellent guide
    10 ft BUD. Uniden Supra analog c/ku, Pansat 9200 HD, Azbox Elite, chaparral co-rotor 2, Astrotel Precision Model PMJ-LNB (C) 15 K noise. Eagle Aspen 770 KU O.6 DB LNB

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  

SatelliteGuys.US | 46 Miami Avenue | Newington, Connecticut 06111
Links monetized by VigLink