    Ordered Directv, would like to pre-wire what I can, help?

    Thanks for the replies. After posting this question I read about the requirement for solid copper wire, the wire I have is copper clad, so I may let him do most of it. The problem is the access is through a crawlspace, and the main TV is inside a converted fireplace. The crawlspace is tight...
  2. L

    Ordered Directv, would like to pre-wire what I can, help?

    I ordered directv with two HR-24s and one standard SD receivers. It will be wire for MRV and with the cinema connection kit. What is the wiring scheme for that like. Any help would be great. thanks, chris
  3. L

    Albany, GA local progamming info needed.

    Thanks for the info. Am about to pull the trigger for Directv over Mediacrap cable
  4. L

    Albany, GA local progamming info needed.

    Yeah, I know they offer these but on their website it says SD for the top three but on a few list and from a few other post on other sites it seems they might actually be HD. I was hoping someone in my DMA could confirm or not if they are actually in HD.
  5. L

    Albany, GA local progamming info needed.

    I am about to pull the trigger on D* but need some help. If anyone here is in the Albany, GA DMA please let me know if ABC (WJXX) and CW is in HD. When looking up the locals for my address on D* site they show as SD, but when researching it, it seems they are in HD. One list here says HD...
  6. L

    dtv installer says grounded...i am not sure

    If the main ground is reachable, close to the grounding block, you run a ground wire (10 gauge) to the main ground. If it is not reachable, not close enough, then you are best to run a ground rod as close to the grounding block as possible and then bond that rod to the main ground with 6 gauge...
  7. L

    dtv installer says grounded...i am not sure

    The NEC code says to ground to the water pipe as a main ground, you must do so within 5 feet of where it enters the building. And for good reason as I found at with my house. I am in the processes of installing an antenna and dish. I was trying to find the main ground and it was not with the...
  8. L

    dtv installer says grounded...i am not sure

    That is not a good ground. Actually, to be in code, if you ground a Dish to its own grounding rod apart from the house ground you must bond the two grounds together with a 6 gauge wire. So not only is your ground bad, the ground needs to be in the dirt, it also needs to be bonded to the house...