Thanks for the answer. I will be calling my local electric company and see what they say.
I have been doing a bit of research and found the following clip:
Grounding the antenna by wendell carter
The National Electric Code requires that the antenna structure be grounded to protect the installation from lightning. A 6AWG copper conductor may be used to connect the Antenna Metal Structure to the building ground system, if it is less than 20 feet. Keep the run as straight as possible.
If the distance exceeds 20 feet, a UL listed ground rod may be installed near the antenna, but the ground rod must be bonded to the building ground with 6AWG minimum copper conductor. A 10AWG copper conductor or larger may connect the antenna to the driven ground rod.
Where the coaxial cable enters the building, a coaxial grounding device must be installed to ground the shield. It must be connected to the building ground with a 14AWG or larger copper conductor.
It is strongly advised that a quality surge protection device (listed by UL1449 Revised) be used to terminate the coaxial cable at the satellite receiver. The surge protector should provide for the power connection, telephone connection, and local antenna connection, if needed. If a local antenna is used for TV reception, it must be grounded in the same manner as the satellite dish.
That being said.....My mast is located 160 feet away from where my electric meter is located and where I assume the main ground is. From what I gather, I can put a grounding rod near the mast..but have to run a wire 160 feet to the main ground near my meter...does that sound correct based on the clip? I'm contecting my Electric company, but want to know if I understand the clip correctly..hehe The coax is already grounded with at bock before it enters the house.