unstable meter - still better than no meter
I have several of those meters and close clones.
I've found so many creative ways to use them.
Even have a special rig with two meters and power splitters for peaking two DBS birds in real time.
One thing I've noticed, is when you turn the knob up too far, the meter circuit seems to oscillate.
This is especially easy to do if you are not aimed at a bird.
(my fault for turning it up too high when I can't get an indication)
So as unfriendly as this seems, try to keep the knob turned to the less-sensitive direction while hunting/finding birds.
When I find the one I want, I try to set the knob for a reading of about 6, and if moving the dish raises the reading past 8, then adjust the meter back down to around 6, again.
With some practice, you should be able to tell by the unstable sound, that the meter is oscillating and not getting a satellite.
(comes with experience)
If in doubt, turn it down, even so far as to have your peak signal as low as 3, if that works better for you.
Of the three (?) I have, at least one if more oscillation-prone than the others.
I've meant to open it up and see if better bypassing or some other trick would help.
But, I use them infrequently, and usually just put up with the problem and get past it.
So, my point is, it's quite possible that some function of the meter oscillating, generates noise that interferes with the 22khz tone/diseqc commands on the coax.
(and the motor wouldn't get the
move command)
That would support the claims of WEC4104, so we don't need to send him to the funny-farm.